爱购彩

  • <tr id='nAgqDo'><strong id='nAgqDo'></strong><small id='nAgqDo'></small><button id='nAgqDo'></button><li id='nAgqDo'><noscript id='nAgqDo'><big id='nAgqDo'></big><dt id='nAgqDo'></dt></noscript></li></tr><ol id='nAgqDo'><option id='nAgqDo'><table id='nAgqDo'><blockquote id='nAgqDo'><tbody id='nAgqDo'></tbody></blockquote></table></option></ol><u id='nAgqDo'></u><kbd id='nAgqDo'><kbd id='nAgqDo'></kbd></kbd>

    <code id='nAgqDo'><strong id='nAgqDo'></strong></code>

    <fieldset id='nAgqDo'></fieldset>
          <span id='nAgqDo'></span>

              <ins id='nAgqDo'></ins>
              <acronym id='nAgqDo'><em id='nAgqDo'></em><td id='nAgqDo'><div id='nAgqDo'></div></td></acronym><address id='nAgqDo'><big id='nAgqDo'><big id='nAgqDo'></big><legend id='nAgqDo'></legend></big></address>

              <i id='nAgqDo'><div id='nAgqDo'><ins id='nAgqDo'></ins></div></i>
              <i id='nAgqDo'></i>
            1. <dl id='nAgqDo'></dl>
              1. <blockquote id='nAgqDo'><q id='nAgqDo'><noscript id='nAgqDo'></noscript><dt id='nAgqDo'></dt></q></blockquote><noframes id='nAgqDo'><i id='nAgqDo'></i>
                推广 热搜: 比选公告  流标公告  竞标公告  信息公告  补充公告  采购公告  磋商公告  二次公告  1940CIC2P100]-招标公告  【重新招标】招标公告 

                【设备类】中国电建水电十一局海外事业部津巴布韦旺吉电厂三期扩建项目空调机组采购项目竞标

                   日期:2021-05-20     来源:中国电力招标采购网    作者:dlztb    浏览:0    
                核心提示:? 竞标公告(公开竞标)项目编号:POWERCHINA-0111009-21032一、竞标条件水电十一局海外事业部(以下简称“采购人”)以公开竞标

                ? 竞标公告(公开竞标)

                项目编号:POWERCHINA-0111009-21032

                一、竞标条件

                水电十一局海外事业部(以下简称采购人)以公开竞标方式采购津巴布韦旺吉项目变电站区域空调机组设备,采购设备计划使用项目工程款资金用于本次竞标后所签订合同的支付。

                二、项目概况、竞标范围

                1、项目概况:津巴布韦Hwange电厂扩建工程位于津巴布韦首都哈拉雷西约485km远的Hwange,位于津巴布韦Victoria Falls机场东南约80km处。Hwange位于津巴布韦〓西部,隶属于Matabeleland North省。本期扩建7#\8# 2x335MW机组。

                2、竞标范围:?

                ? 项目变电站区域分体空调采购,清单如下:

                Table 4.2-1 Hwange B 主控楼 (N0101)

                序号

                No.

                项目名称

                Item name

                参数

                Technical specification

                单位

                Unit

                数量

                QTY

                安装位置

                Location

                备注

                Remark

                1

                防爆特高温分体壁←挂空调器(含室外机)

                Explosion-proof wall-mounted split A.C. (Include outdoor unit)

                QL=7.5kW QR=8kW

                N4000W

                230V 单相 50Hz

                Set

                3

                蓄电池室

                T3工况,冷媒管常规长≡度,带导除静电接地装置。防爆满足IEC60079要求。

                T3 working condition

                2

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=10kW QR=10kW

                N3900W

                400V三相 50Hz

                Set

                3

                交直流配电间

                T3工况,冷媒管▽常规长度

                T3 working condition

                3

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=12kW QR=14kW

                N3300W[A1]

                400V三相 50Hz

                Set

                2

                通信机房

                T3工况,冷媒管常规长度

                T3 working condition

                4

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=3.5kW QR=3.8kW

                N1360W

                230V 单相 50Hz

                Set

                2

                控制室

                T3工况,冷媒管常规长度

                T3 working condition

                5

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=12kW QR=14kW

                N3300W[A2]

                400V三相 50Hz

                Set

                7

                继电器室

                T3工况,冷媒管常规长度

                T3 working condition

                6

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=5kW QR=5.45kW

                N2050W

                230V 单相 50Hz

                Set

                2

                男、女更衣室

                T3工况,冷媒管常规长度

                T3 working condition

                7

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=7kW QR=7.3kW

                N2570W

                230V单相 50Hz[A3]

                Set

                2

                会议室

                T3工况,冷媒管常规长度

                T3 working condition

                8

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=7kW QR=7.3kW

                N2570W

                230V单相 50Hz[A4]

                Set

                10

                办公室

                T3工况,冷媒管常规长度

                T3 working condition

                7

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=7kW QR=7.3kW

                N2570W

                230V单相 50Hz[A5]

                Set

                2

                厨房、餐厅

                T3工况,冷媒管常规长度

                T3 working condition

                 

                Table 4.2-2 Hwange B 400V配电间 (N0102)

                序号

                No.

                项目名称

                Item name

                参数

                Technical specification

                单位

                Unit

                数量

                QTY

                安装位置

                Location

                备注

                Remark

                1

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=12kW QR=12kW

                N4800W

                400V三相 50Hz

                Set

                3

                400V配电间

                T3工况,冷媒管常规长度

                T3 working condition

                2

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=2.6kW QR=3.0kW

                N950W

                230V 单相 50Hz

                Set

                2

                大、小储藏室

                T3工况,冷媒管常规长度

                T3 working condition

                3

                移动式工业空调器

                Removal industrial A.C.

                QL=4.5kW QR=4.5kW

                N1800W

                230V 单相 50Hz

                Set

                2

                检修间

                T3工况,冷媒管常规长度

                T3 working condition

                 

                 

                Table 4.2-3 Hwange B 警卫室 (N0103)

                序号

                No.

                项目名称

                Item name

                参数

                Technical specification

                单位

                Unit

                数量

                QTY

                安装位置

                Location

                备注

                Remark

                1

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=10kW QR=10kW

                N3900W

                400V三相 50Hz

                Set

                1

                接待室

                T3工况,冷媒管常规长度

                T3 working condition

                2

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=5kW QR=5.45kW

                N2050W

                230V 单相 50Hz

                Set

                1

                办公室

                T3工况,冷媒管常规长度

                T3 working condition

                3

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=2.6kW QR=3.0kW

                N950W

                230V 单相 50Hz

                Set

                1

                厨房

                T3工况,冷媒管常规长度

                T3 working condition

                 

                Table 4.2-4 Sherwood B 主控楼 (N0201)

                序号

                No.

                项目名称

                Item name

                参数

                Technical specification

                单位

                Unit

                数量

                QTY

                安装位置

                Location

                备注

                Remark

                1

                防爆特高温分体壁挂空调器(含室外机)

                Explosion-proof wall-mounted split A.C. (Include outdoor unit)

                QL=7.5kW QR=8kW

                N4000W

                230V 单相 50Hz

                Set

                3

                蓄电池室

                T3工况,冷媒管常规长度,带导除静电接地装置。防爆满足IEC60079要求。

                T3 working condition

                2

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=10kW QR=10kW

                N3900W

                400V三相 50Hz

                Set

                3

                交直流配电间

                T3工况,冷媒管常规长度

                T3 working condition

                3

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=12kW QR=14kW

                N3300[A6]W

                400V三相 50Hz

                Set

                2

                通信机房

                T3工况,冷媒管常规长度

                T3 working condition

                4

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=3.5kW QR=3.8kW

                N1360W

                230V 单相 50Hz

                Set

                2

                控制室

                T3工况,冷媒管常规长度

                T3 working condition

                5

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=12kW QR=14kW

                N3300W[A7]

                400V三相 50Hz

                Set

                7

                继电器室

                T3工况,冷媒管常规长度

                T3 working condition

                6

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=5kW QR=5.45kW

                N2050W

                230V 单相 50Hz

                Set

                2

                男、女更衣室

                T3工况,冷媒管常规长度

                T3 working condition

                7

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=7kW QR=7.3kW

                N2570W

                230V单相 50Hz[A8]

                Set

                2

                会议室

                T3工况,冷媒管常规长度

                T3 working condition

                8

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=7kW QR=7.3kW

                N2570W

                230V单相 50Hz[A9]

                Set

                10

                办公室

                T3工况,冷媒管常规长度

                T3 working condition

                7

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=7kW QR=7.3kW

                N2570W

                230V单相 50Hz[A10]

                Set

                2

                厨房、餐厅

                T3工况,冷媒管常规长度

                T3 working condition

                 

                Table 4.2-5 Sherwood B 400V配电间 (N0202)

                序号

                No.

                项目名称

                Item name

                参数

                Technical specification

                单位

                Unit

                数量

                QTY

                安装位置

                Location

                备注

                Remark

                1

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=12kW QR=12kW

                N4800W

                400V三相 50Hz

                Set

                3

                400V配电间

                T3工况,冷媒管常规长度

                T3 working condition

                2

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=2.6kW QR=3.0kW

                N950W

                230V 单相 50Hz

                Set

                2

                大、小储藏室

                T3工况,冷媒管常规长度

                T3 working condition

                3

                移动式工业空调器

                Removal industrial A.C.

                QL=4.5kW QR=4.5kW

                N1800W

                230V 单相 50Hz

                Set

                2

                检修间

                T3工况,冷媒管常规长度

                T3 working condition

                 

                Table 4.2-6 Sherwood B SVC主控楼 (N0203)

                序号

                No.

                项目名称

                Item name

                参数

                Technical specification

                单位

                Unit

                数量

                QTY

                安装位置

                Location

                备注

                Remark

                1

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=14kW QR=14kW

                N5200W

                400V三相 50Hz

                Set

                5

                控制及ACDC

                T3工况,冷媒管常规长度

                T3 working condition

                2

                防爆特高温分体壁挂空调器(含室外机)

                Explosion-proof wall-mounted split A.C. (Include outdoor unit)

                QL=7.1kW QR=8.1kW

                N4000W

                230V 单相 50Hz

                Set

                2

                蓄电池室

                T3工况,冷媒管常规长度,带导除静电接地装置。防爆满足IEC60079要求。

                T3 working condition

                3

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=6kW QR=6.4kW

                N2350W

                400V三相 50Hz

                Set

                2

                备品间

                T3工况,冷媒管常规长度

                T3 working condition

                4

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=10kW QR=10kW

                N3900W

                400V三相 50Hz

                Set

                2

                #1水机室

                T3工况,冷媒管常规长度

                T3 working condition

                5

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=10kW QR=10kW

                N3900W

                400V三相 50Hz

                Set

                2

                #2水机室

                T3工况,冷媒管常规长度

                T3 working condition

                6

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=7kW QR=7.3kW

                N2570W

                230V单相 50Hz

                Set

                2

                阀控室

                T3工况,单套冷媒管长度不少于22

                T3 working condition

                 

                Table 4.2-7 Sherwood 警卫室 (N0204)

                序号

                No.

                项目名称

                Item name

                参数

                Technical specification

                单位

                Unit

                数量

                QTY

                安装位置

                Location

                备注

                Remark

                1

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=10kW QR=10kW

                N3900W

                400V三相 50Hz

                Set

                1

                接待室

                T3工况,冷媒管常规长度

                T3 working condition

                2

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=5kW QR=5.45kW

                N2050W

                230V 单相 50Hz

                Set

                1

                办公室

                T3工况,冷媒管常规长度

                T3 working condition

                3

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=2.6kW QR=3.0kW

                N950W

                230V 单相 50Hz

                Set

                1

                厨房

                T3工况,冷媒管常规长度

                T3 working condition

                 

                Table 4.2-8 Insukamini 二次设备室 (N0301)

                序号

                No.

                项目名称

                Item name

                参数

                Technical specification

                单位

                Unit

                数量

                QTY

                安装位置

                Location

                备注

                Remark

                1

                防爆特高温分体壁挂空调器(含室外机)

                Explosion-proof wall-mounted split A.C. (Include outdoor unit)

                QL=7.5kW QR=8kW

                N4000W

                230V 单相 50Hz

                Set

                3

                蓄电池室

                T3工况,冷媒管常规长度,带导除静电接地装置。防爆满足IEC60079要求。

                T3 working condition

                2

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=7kW QR=7.3kW

                N2570W

                230V单相 50Hz[A11]

                Set

                4

                交直流配电间

                T3工况,冷媒管常规长度

                T3 working condition

                3

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=10kW QR=10kW

                N3900W

                400V三相 50Hz

                Set

                5

                控制及继电器室

                T3工况,冷媒管常规长度

                T3 working condition

                 

                Table 4.2-9 Insukamini 400V配电间[A12] (N0302)

                序号

                No.

                项目名称

                Item name

                参数

                Technical specification

                单位

                Unit

                数量

                QTY

                安装位置

                Location

                备注

                Remark

                1

                分体吸顶式空调器(含室外机)

                Ceiling split A.C. (Include outdoor unit)

                QL=10kW QR=10kW

                N3900W

                400V三相 50Hz

                Set

                3

                400V配电间

                T3工况,冷媒管常规长度

                T3 working condition

                 

                Table 4.2-10 电厂升压站 (FA16721S-N0101)

                序号

                No.

                项目名称

                Item name

                参数

                Technical specification

                单位

                Unit

                数量

                QTY

                安装位置

                Location

                备注

                Remark

                1

                防爆特高温分体壁挂空调器(含室外机)

                Explosion-proof wall-mounted split A.C. (Include outdoor unit)

                QL=5kW QR=5.3kW

                N1880W

                230V 单相 50Hz

                Set

                3

                蓄电池室

                T3工况,冷媒管常规长度,带导除静电接地装置。防爆满足IEC60079要求。

                T3 working condition

                2

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=5kW QR=5.45kW

                N2050W

                230V 单相 50Hz

                Set

                3

                交直流配电间

                T3工况,冷媒管常规长度

                T3 working condition

                3

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=5kW QR=5.45kW

                N2050W

                230V 单相 50Hz

                Set

                3

                继电器室

                T3工况,冷媒管常规长度

                T3 working condition

                4

                分体壁挂空调器(含室外机)

                Wall-mounted type split A.C. (Include outdoor unit)

                QL=5kW QR=5.45kW

                N2050W

                230V 单相 50Hz

                Set

                3

                通信机房

                T3工况,冷媒管常规长度

                T3 working condition

                 

                3、交货时间:2021年7月15日?

                4、交货

                2产品的性能及业绩要求。近三年投标人应具有类似海外工程供货业绩。在专业技术、设备设施、人员组织、业绩经验等方面具有设计、制造、质量控制、经营管理的相应的资格和能力。具有完善的ISO9001质量保证体系。投标人应设计、生产过类似设备并安全稳定运行3年以上的业绩,并能提供说明资料和证明文件;近5年内有同类设备的出口业绩者优先。

                .3财务上独立、合法运作并独立于招标人和招标机构。具有良好的银行资信和〗商业信誉,近三年没有处于被责令停业,财产被接管、冻结、破产状态,资金周转不存在困难。

                4法定代表人为同一个人的两个及两个以上法人,母公司、全资子公司及其控股公司,只能有一家单位参加本标的投标。

                5、本次招标不接受联合体投标。

                6、投标人不存在《中华人民共和国招标投标法》、《中华人民共和国招标投标法实施条例》禁止投标的情形。

                四、竞标文件的获取

                1、凡满足本公告规定的竞标响应人资格要求并有意参加竞标者,2021年05月28北京时间)在中国电建设备物资集中采购平台(https://,以下简称集采平台)获取竞标文件。

                五、竞标响应文件的递交

                1、投标文件递交的截止时间(投标截止时间,下同)为2021531日10时00分

                没有在中国电力招标采购网(www.dlztb.com)上注册会员的单位应先点击注册。登录成功后根据招标公告的相应说明获取招标文件!

                联系人:李杨
                咨询电话:010-51957458?
                手 机:13683233285?
                传 真:010-51957412?
                QQ:1211306049?
                微信:Li13683233285
                邮箱:1211306049@qq.com

                来源:中国电力招标采购网?编辑:

                bid.powerch
                 
                打赏
                扫一扫快速入网
                 
                更多>同类资讯

                最新资讯
                最新行情
                Powered By DESTOON